Troy 500 Serial Server Hub
Components used during the image capture phase (March 2006-March 2007):The cameras were installed on the Ex-Centris roof in January 2006. Following a test phase, each camera captured 1,024 images per day for one year between March 23, 2006, and March 21, 2007, beginning 15 minutes after sunrise (to assure sufficient light). The images were captured at the rate of two per minute in JPEG format, 1280x1024 pixels. In all 745,000 images were captured and stored in a 226 GB database.
Rinstrum C500 Series bringing together 25 years of smart weighing. Lua Programmability. Compact ½ DIN standard housing. 10,000d @ 0.5 µ V/d OIML R76. European WELMEC compliant legal for trade data storage. Embedded Linux operating system. Lua programmability. Modbus ASCII, RTU, TCP/IP.
This 8-port USB-to-serial adapter hub provides an easy and cost-efficient way to add RS232 serial capability to your industrial setting. It features a sturdy, rack-mountable chassis, and supports daisy chaining, so you can connect multiple hubs together to increase your serial device port count.
A scalable solution for changing needsThis rack-mountable USB serial hub (FTDI) lets you add eight serial ports (RS232), with full control from your desktop or laptop computer system using a single USB port. The daisy-chain function gives you a cost-effective and scalable way to increase your serial port count and expand as your needs grow, without investing in a more expensive serial hub.Providing full control of your serial components from a single device, the USB serial hub is ideal for a multitude of applications including industrial automation, self-serve automated kiosks, and monitoring of cameras and security systems. Built-in convenienceThe hub features COM port retention, which retains the assigned serial COM port values. This ensures that the same values are automatically re-assigned to the port provided by the adapter, in the event it is disconnected and re-connected to the host computer.The hub features a reliable FTDI USB-to-serial chipset, which provides easy installation into a broad range of operating systems. Meets the demands of industrial environmentsWith its all-metal chassis, this rugged, rack-mountable hub fits into standard 19-inch server storage racks to provide an efficient industrial serial solution.
It supports an extended operating temperature range of -40°C to 85°C (-40°F to 185°F), ensuring reliable performance even in the harshest environments. The USB-serial hub includes both an AC adapter and terminal block power, providing versatile power options.The ICUSB23208FD is backed by a StarTech.com 2-year warranty and free lifetime technical support. Before you install drivers and software for the device, make sure that your operating system is current (for example, the most recent service pack is installed). Download the latest drivers from the StarTech.com website. You can find the part number and product ID on the product’s packaging.Note: Windows will typically save the files to the Downloads folder that is associated with your user account (for example, C:Users yournameDownloads). Once the download is complete, right-click the zip folder that you downloaded, select Extract All, and follow the on-screen instructions.
In the list of extracted files, right-click the CDM21214Setup.exe file and select Run as Administrator.Note: If the Run as Administrator option is not available, you might be attempting to run the installer from within the zipped file. Please extract the files using the instructions in Step 2. Follow the on-screen prompts to install the device drivers and restart the computer when prompted. Your computer will automatically complete the driver installation and your device should be ready to use. To confirm that Windows detects your USB device, complete the following:. Press the Windows key+ R, type devmgmt.msc, and press Enter.
In Device Manager, under the appropriate heading, confirm that your expansion card is listed and that there isn't an exclamation mark next to it. For example, a USB controller card would be under Universal Serial Bus controllers.Your USB device is listed according to the name of the chipset. To determine the name of the chipset of your USB device, navigate to and look on the Technical Specifications tab for your product. To confirm that the Mac OS detects your USB device, complete the following:. Click the Apple icon. Click About This Mac. Click More Info or System Report.
Under the appropriate heading, confirm that your USB device is listed and that there isn't an error. For example, a network card would be under Ethernet Cards.You may need to refresh the System Information page after you plug in your device. To do so, press Command + R with the System Information page open.Your USB device is listed according to the name of the chipset. To determine the name of the chipset of your USB device, navigate to and look on the Technical Specifications tab for your product. When you troubleshoot issues with a serial device, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:.Serial cables.Serial ports.Serial devicesTo test your setup components, try the following:.Use the serial cable, serial port, and serial device in another setup to see if the problem is with the components or the setup.Use a different serial cable, serial port, and serial device in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.When you test your cables, it is recommended that you do the following:.Test each cable individually.Use short cables when you are testing.When you test the serial ports and serial device, it is recommended that you do the following:.Press the Windows key + R, type devmgmt.msc, and press Enter to open Device Manager.
They all stay up to date, all the time with Cloud Sync.All new interface.Budgeting has never looked this good. Ynab 4 activation keygen music. Install YNAB on as many computers as needed (work, laptop, or desktop on Windows or Mac). Break account balances into meaningful categories, save for longer-term goals, and quickly determine if that impulse purchase will affect your finances adversely now and down the road.Cloud Sync - stay on budget everywhere.Check balances and record transaction on the go with your phone.
Check to see if your device is listed under Ports (COM & LPT).Make sure that the COM port number is the correct number for the serial device and that the software being used to connect the computer to the serial device uses the correct COM port number.If you do not see the COM port number in Device Manager see this FAQ for PCI/PCIe expansion cards:or this FAQ for USB devices:.If the device is listed with an error, follow the instructions on the website to reinstall the drivers.Note: Some serial devices work only if the COM port number is between a certain range. For example, COM1 to COM4.Perform a serial loopback test. See this FAQ on how to perform a RS-232 serial loopback test. To check whether or not an RS-232 serial port is working, perform an RS-232 loopback test by doing the following:. If your serial port is not female, convert it by taking a female/female cable or gender changer and plugging it into the serial port. Take a metal paperclip or wire and cross pins 2 and 3. If you look closely at the female end, the pins should be numbered.
Open a telnet session on the COM port number of the device that you are testing. To find out the COM port number, refer to the following FAQ:.Note: To open a telnet session on the COM port, you need a telnet client like PuTTY or Hyper Terminal.
Windows XP comes with Hyper Terminal. When the session is open, anything you type into it you should see. The loopback test fails when you cannot see what you are typing.If the loopback test fails, make sure that the serial cable or gender changer that you are using works and that the adapter is in the correct port.You can check multiple ports at the same time by opening multiple sessions, putting the loopback adapter on one port, and trying to type into each session. When you can see what you are typing, you know that the COM port is working and you can see which port number the physical serial port is. Close the window for the port that you just tested to speed up the testing of the remaining serial ports.For products related to this article, click.
California Proposition 65 WarningWarning: Cancer and reproductive harm — Safety Measures. If product has an exposed circuit board, do not touch the product under power.
Troy 500 Serial Server Hubs
If Class 1 Laser Product. Laser radiation is present when the system is open. Wiring terminations should not be made with the product and/or electric lines under power. Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines. Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.